In Florida, we always insulate horizontal portions of the drain because we would have consistent growth and water damage issues due to the high dew points if we didn't. Good tips and knowledge. A condensing gas-fueled tankless water heater would be expected to operate at a greater overall fuel efficiency than a comparable non-condensing unit. Dont forget to check out our YouTube page. These will allow me to attach clear vinyl tubing that will tie in to the air handler at the top and exit the wall at bottom just below the sink. My a/c in my apartment was under performing , so I took a look at the F.A.U. HOWEVER, new wording was added in IMC 307.2.4.1 that states that ductless systems must either have a check valve or a trap in the condensate line. Recently learned for 5 ton draw-through systems, the 3/4 PVC exiting the coil needs several inches of vertical drop to sufficiently create enough water volume & weight to stop back pressure which clearly created spillage/leakage from the drain pan. . Your HVAC or AC unit condensate should be trapped close to the unit When we are mounting to the deck, I use cut-off PVC piping to create stanchions, and reinforce the downward grade, off the service platform. A condensing gas-fueled tankless water heater recaptures much of the heat that would have gone up the flue, uses it to help heat the domestic hot water, and produces a much-cooler exhaust and condensate that is typically vented through PVC piping to the exterior. While venting is a common best practice, it isn't part of the IMC code. InspectAPedia tolerates no conflicts of interest. InspectAPedia tolerates no conflicts of interest. Obviously, I need to ask the builder why he didnt use the sink in the laundry room. That's to primarily avoid the risk of sewer gases backflowing up into the unit as can occur in some drain disposal circumstances. The method of drainage shall comply with applicable Federal, State, and local laws and regulations relating to pollution control or the protection of the environment. My company recently changed out all the hvac equipment at an apartment complex. It is the final part of his series on zonal pressure diagnostics. I think the builder cramped as much into that small space to save money. Updated 3/4/2022 Picking up where we left off in part 2 of the series, we discussed how a pressure reading from an attached zone indicates only the ratio of the [], 2023 - HVAC School | All rights reserved. Condensate waste and drain line size shall be not less than 3/4-inch (nominal) diameter from the drain pan connection to the place of condensate disposal. The flood-level rim of the receptor shall be not less than 6 inches (152 mm) lower than the lowest Since the wall is interior I'll build a shallow (about 6" deep) soffit at the top of the wall that will be the same dimensions as the air handler which will mount on the front. [7] 2006 ICC Model Building Code Chapter 3, General Regulations, New Jersey Mechanical Code, web search 8/2/2012, original source: http://www2.iccsafe.org/states/newjersey/NJ_Mechanical/PDFs/2006_Chapter%203-General%20Regulations.pdf. appliance, device or apparatus, may discharge into, the drainage system" 3. Naturally this type of installation precludes running the condensate drain up with the line-set. [10] "Whirlpool WGPH45 Packaged Heat Pump, Product Specifications", Whirlpool Corporation, [copy on file]. stock code: afs-le85-2. Notice that one of the most common condensate disposal locations, connection to a plumbing stack vent pipe, is not recommended and is prohibited by building code in some jurisdictions. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. I just had a furnace and cooling coil installed in my attic area. According to the IMC, 3/4 is sufficient for up to 20 tons unless the drain outlet size is larger than 3/4. by InspectApedia-911 (mod). Please find your question repeated along with a detailed reply now at Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. A/C condensate drains & pumps: codes, installation, leaks, clogs, connections, troubleshooting & repair: This article discusses the inspection and repair or un-clogging of condensate disposal systems, including air conditioning, heat pump or condensing boiler/furnace condensate drains & condensate pumps, and their proper installation as part of our review of condensate piping, traps, drains, Multiple pipes in a manifold configuration shall be sized in accordance with an approved method. Which allows only condensate and gases to drain from steam pipe lines a.Traps b. No. - ICC IMC 307.2.5 & IRC M1411.3.3 Drain Line Maintenance code for 2015, original source: http://www.iccsafe.org/, Devices or methods for providing condensate drain cleaning or de-clogging are discussed in this companion, article: CONDENSATE DRAIN CLEAN & DE-CLOG, The following HVACR condensate disposal recommendations summary cites, paraphrases, & comments on the widely adopted 2006 ICC model building code section on condensate disposal, section 307 [7], For the two Types of Condensate: Fuel burning devices vs Evaporators & cooling coils. To clarify, an indirect waste pipe is something that is upstream of a trap. Above: a pipe insulation table from the New York 2010 Energy Code. Hey, so we recently brought a house in MA and have come across this: the HVAC is connected to a standpipe for a washer via a tube. "The information in this guide is a summary of requirements 2. Thank you for your help with this matter. AND DRAIN TRAP INSTRUCTIONS, Intertek CVC96 7 MVC96 TWO STAGE GAS FURNACE INSTALLATION INSTRUCTIONS, RECTORSEAL EZ TRAP CONDENSATE DRAIN LINE INSTRUCTIONS, RHEEM NON-CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL, AMERICAN COMMERCIAL CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL, ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, 307.2: " Condensate shall not mechanical service equipment; electrical components; automotive; domestic refrigeration; . The condensate drain from mechanical equipment is regulated by the mechanical code. Potentially the largest coordination item between the mechanical and plumbing disciplines is the requirement for drains. This would allow me to run from the hall where the unit and 11' ceiling is to areas where the ceiling is 10' and continue to where drain terminates. Quoting, Also see: specific condensate drain installations for your specific air conditioner, heat pump, or condensing gas furnace. You'll see that in Texas there is not much chance that the condensate drain is going to be running at the operating temperature ranges ( 105F (40C) or below 55F ) cited here. Can I use a little giant type condensate pump with 3/4 into the pump, and 3/8 out of it? This gives your drain pipe a uniform look and makes it easy for the inspector to pass your job. The ICC, under "Drain Line Maintenance" requires that Condensate drains shall be configured to permit the clearing of blockages and performance of maintenance without having to cut the line. We did not find cleaning requirements for condensate drip trays cited in the model building codes surveyed to date. The tables of pipe insulation shown here are interesting in that each gives insulation thickness required in inches without specifying the insulation material though Table 503.2.8 does give an assumed R-value per inch of insulation. Whether its to support the drain line with hangars, or to strap it down to the deck, we dont want the PVC to bow downwards, creating a dip and not allowing gravity to do its thing. But that excerpt really isn't talking about condensate drains when read in context. Your email address will not be published. Thats the most popular type of piping HVAC installers use today, but we can also use ABS, cast iron, or hard drawn copper. CONDENSATE DRAIN INSULATION REQUIREMENTS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. RT Quick Angle Grinder - 601078420 from METABO. Its the contractors responsibility to give them a choice and educate them about the options and what the thorough diagnostic process looks like, including balancing the home and checking the pressure in relation to the outdoors. That helps ensure that that the water properly trips the switch instead of overflowing out of the vent if a backup occurs. I have direct access to an exterior wall, and the condensate from my HVAC (right next to the water heater) in fact already had its own condensate drain running outside. When doing load calculations (Manual J), we need to know how much of the heat load, especially the latent heat load, comes from leakage in the building envelope and the ducts. @jacinto raquel, Don't dump condensate around foundations, basements, or other areas that could cause ponding, erosion, or leakage. Sharing a condensate drain downstream from the AC unit MIGHT be OK provided its capacity is not exceeded and of course that the condensate drain is installed to drain to an acceptable location (such as outdoors, not onto a sidewalk etc) and terminates where it won't be blocked by snow, shrubbery, etc. while submerged in water. . The complex is now owned by a new owner and he has contacted us about why we didn't insulate the condensate drain lines that are inside the return air in an air conditioned space. Ive got 20 units tied into a 2 inch pipe and recently it started getting backed up.. For structures located in flood hazard areas, mechanical systems, equipment and appliances shall be located at or above the elevation required by Section 1612 of the International Building Code for utilities and attendant equipment. While moisture in a crawl space can cause damage over time, this is not the intent of this section. We discuss air conditioning, heat pump & condensing boiler or furnace condensate drain leaks, locations, causes, repairs. Is it a requirement to install a cleanout for existing systems that need drain cleared but do not have one? Wow, this blog got a little long! Plumbing Code (UPC) and the 2005 National Electrical Code." My warranty company will not cover modification to my condensate drain line because the "items not covered" in my contract list the condensate pump.". what is the code for the primer used for gluing pvc schdule 40 pipe for refrigeration evaporators in a 36 degree cooler? From what I can tell, both local code (IPC 2018) and the water heater install guide only say that the condensate line needs an air gap. That leaves us a lot of wiggle room for interpretation and a lot of authority to the AHJ (authority having jurisdiction) and design professionals to establish what is and what isn't an approved location. Here are a few good guidelines: IMC 307.2.2 tells us that an A/C condensate drain inside diameter should not be smaller than 3/4 and should not be smaller than the drain pan outlet diameter. --- thanks, In order for a system that has 20 drain lines draining into a single 2-inch pvc pipe you must have all 20 traps designed properly and all must contain a water seal. P.S. IMC 307.1 and CMC 310.1 talk about condensate from the cooling coils were installing in peoples homes. In some areas of the United States, a gel-like or slime-like substance may be seen in the base pan. The residential unit has significant airflow capacity of up to 601m3hr* and are suitable for handing airflow directions and . I've not found a requirement for insect screens on those outlets and in fact there may be a concern that such screens risk drain clogging and backups. Steam trap c.Steam Loop d. Steam tap. That means we cannot dump into anything downstream of a trap. Those are not usually very noisy; check for malfunction, for mounting on padding, for alternative models, for relocation to a more remote spot that can still pump up to the necessary drain. Ask the new owner to be more-specific about any damage or problem conditions she's seeing - maybe send along a photo. My OPINION is that the pump itself - the container and motor, sold as a unit - is separable from the drain piping or tubing. While most manufacturers don't specify this on gravity ductless drains, it is something to look out for. For the secondary drain system he installed a wet switch within the pan below the unit which will turn the unit off upon water detection. About the Business. RHEEM NON-CONDENSING TANKLESS WATER HEATER INSTALLATION MANUAL [PDF] In this series of blogs, Im simply trying to open a conversation about codes we cite on the job every day out there without even knowing it. When the mixture returns to its use temperature, the condensation will transform back to the gaseous state. When it comes to the mechanical code, there is no "nationally adopted code," but most states and localities adopt the International Mechanical Code (IMC). IMC 307.2.3 states that all HVAC equipment that produces condensate must have either a secondary drain line or a condensate overflow switch, a secondary drain pan with a secondary drain line, a condensate switch, or some combination of these installations should be used to prevent overflow if the primary drain line blocks. ASHRAE Standard 90.1-2010, Section 6.4.4.1 HVAC System Pipe Insulation, lists HVAC piping requirements and as an EXCEPTION, The condensate line material: Sch. Building & mechanical codes do not require insulation on A/C condensate drains, based on a reading of the current U.S. Energy Code that I will excerpt here. Vertical terminations must incorporate a condensate drain and trap as close as possible to the appliance. Im thinking the water heater condensate line may need to just run a short distance and drop into a funnel or something, which then continues straight down and connects to the line out. For other readers: what's the difference between a conventional tankless water heater and a condensing tankless water heater? . I recently had a condensing tankless water heater installed Im trying to determine the proper way to deal with condensate. It appears that this condensate drain only drops into that vertical standpipe an inch or two and if there is still a decent opening around it to let air into the standing drain line then you got an air gap between the end of the condensate drain and the P-trap below so it should be okay. All piping serving as part of a heating or cooling system shall be thermally insulated in accordance with Table 503.2.8. The unit hung as high as possible, 11'-4" at bottom of unit and finished ceiling height is at 11'-0". In practice, it is safer to use 1/4 of fall per foot to ensure proper drainage and provide some wiggle room for error. Materials 10. What about using a condensate trap and using the positive pressure to force the water to the condensate outlet? An indoor disconnect switch. It's often permitted but not the best solution to simply drip condensate into the laundry sink. Air Around the Clock's only business is providing the residents and businesses of Broward County, West Palm Beach, North Miami-Dade, and Jupiter with professional, cost-effective air conditioning, cooling and HVAC repair, air conditioner service and maintenance programs. not less than the drain on the unit, and in no case less than 3 4 of an inch (20 mm). Continue readingat CONDENSATE DISPOSAL, IMPROPER or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. Its a new build. Genry Garcia returns to the podcast to talk about pressures in the building envelope, namely the infiltration skeletons behind closed doors. Enter the email address you signed up with and we'll email you a reset link. Please let us know anything we can do because we need the washer. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Free shipping for many products! [P] 888-ICC-SAFE (888-422-7233) If you're getting PVC pipe joint failures most often that's from improper prepping. If youve ever wanted Fox Family swag, heres your chance to grab the same stuff we wear on the job out in the field! @Hy, Including recorded tech training, interviews, diagnostics and general conversations about the trade. Thanks so much for watching and well see you on the next blog! Air Conditioner Condensate Drain Code The International Mechanical Code (IMC) provides specific rules and regulations on how to install, clean, maintain, and repair your HVAC condensate drain lines. The backfill under and beside the pipe shall be compacted for pipe support. On 2020-01-16 by (mod) - placing an air handler on top of mason bricks sitting inside the drip tray proper installation procedure? Is placing an air handler on top of mason bricks sitting inside the drip tray proper installation procedure? Not illegal but does sound as if there was a problem with the condensate drain system. If the manufacturer requires a trap, then a trap is required. IMC 307.2.5 states that the condensate assembly must be installed so that the drain line can be cleared of blockages and maintained without cutting the drain. Dont forget to get your official Fox Family merch available on Teespring.com. The picture in the article for a 5 ton system would NOTt be nearly enough to overcome the negative air pressure caused by draw-through air pressure and thus result in coil pan pan spillage. Need code reference. Above: Table 503.2.8 Minimum Pipe Insulation Thickness, adapted from the 2010 New York State Energy Conservation Code. Available in over 20 convenient sizes. 5. It would be helpful to know the brand and model of your condensing-type tankless water heater so that together we could consult its installation instructions. Both require an air gap - which you have, and neither should be overwhelming a properly-sized, un-blocked drain. Learn more about the 4th Annual HVACR Training Symposium or buy a virtual ticket today athttps://hvacrschool.com/symposium. I often find that the flexible condensate drain tubing is not carefully installed nor supported to maintain drainage slope throughout its run. Its also possible that this install is totally legit, and the air gap requirement is fulfilled by the gap between the ground and the down pipe outside the house. Is this okay? What is the inside diameter minimum of condensate drains. Condensate waste and drain line size shall not be less than 3/4-inch (19.1 mm) internal diameter and shall not decrease in size from the drain pan connection to the place of condensate disposal. Energy code: Section 503.2.8 Piping insulation. So do let me know if you can find out this detail. Mechanical system piping capable of carrying fluids above 105F (40C), or below 55F (13C) shall be insulated to a minimum of R-2. Is insulation required on the condensate drain pipe? This creates a nuisance area of slippery water that, over time, can even start creating algae which are even more slippery. Strong . damage to any building component could occur as a result of overflow from the equipment drain pan or stoppage of the condensate drain piping: For Indoor Use: Stay in the . broad. i recently found this out on a 5ton Goodman package heatpump. . Proficient in handling the entire gamut of Plant Layout Design, Isometrics, Support Engineering and Stress Analysis.<br>2. If you are making use of a water heater - to produce domestic hot water used for washing and bathing - water flowing through the heater is pushed by building water pressure, from a municipal supply or from a well water pump or a pressure booster pump. Is a Manual J Load Really Necessary on Residential Retrofits? What are the air conditioner condensate drain code? The traps like those shown in Figure 3 are available at many HVAC supply houses. 1.Show primary condensate drain piping on the mechanical plans. Attached is the picture. Significant changes to condensate discharge in the 2021 International Mechanical Code March 8th, 2021 by Building Safety Journal staff Technical Topics A modification to Section 307.2.1.1 (Condensate Discharge) states that significant coverage is added to the code regarding the point of disposal of condensate. [F] (202) 783-2348 Factory-installed piping within room fan-coils and unit ventilators tested and rated according to AHRI 440 (except that the sampling and variation provisions of Section 6.5 shall not apply) and 840, respectively. Special trap product can also provide a seal against sewer gas back-drafting through a dry trap. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); This site uses Akismet to reduce spam. health and safety concerns are reviewed. Drains can be made out of many materials, but PVC is by far the most common. If the condensate lines travel off the service platform and disappear in the insulation, thats fine. CONDENSATE DRAIN INSULATION REQUIREMENTS. Only the discharge of the condensate is regulated by the plumbing code, not the connection of the piping to the mechanical equipment. I have a question regarding the use of a Condensate Removal Pump for a hybrid water heater. Cite this article: FindLaw.com - Code of Federal Regulations Title 9. I want to know if it is ok to run 6', sloped of course, out from the unit before putting in the trap. This is in a ground level garage. Watch out: in our OPINION and as we discuss in these articles, while a trap on a condensate drain line, usually provided quite close to the condensate collection pan itself, can reduce the chances of sewer gases backing up from a condensate drain that has been connected to the building DWV vent piping (not a procedure we recommend), 307.2.3 recommends any of the following methods for handling a backup condensate overflow protection system: Section 307.2.3.1 requires use of a water-level monitoring device to provide condensate overflow protection on equipment where there is no secondary condensate drain and no ability to install an auxiliary condensate drain pan. Excerpt: The condensate drain does not require a trap. This code is widely used to properly dispose of air conditioner drain. [i.e. The following are significant changes to the IMC and its proposed amendments. condensate cannot drain adequately via gravity, usually because the application lacks conventional, below-floor drainage. Certainly there is no conceptual constraint on where a condensate drain can be located, but it has to be in a location that works either by gravity or by a condensate drain pump. This applies to gravity / natural drain with no condensate pump assistance. I saw what the problem was, ( under charged or line blockage). Heat Exchanger 11. The means by which the condensate waste is delivered to the termination point is as important as where we discharge it. Thats pretty much common sense, right? This way my line set can be routed hidden up into the attic above and run to an adjacent wall which is exterior and pass through to the outside. The result is the accumulation of dust, debris, algae or mold in a dip in the drain that leads to clogging and potentially to a backup and leak of condensate out at the air handler. Runout piping not exceeding 4 feet (1219 mm) in length and 1 inch (25 mm) in diameter between the control valve and HVAC coil. N1103.3 Mechanical system piping insulation. An effective communicator with excellent relationship building & interpersonal skills. The vent opening should always rise above the trip level of the condensate overflow switch when it is in the primary drain line or pan or above the secondary/aux overflow port on the primary drain pan. That HVAC drain runs right beneath where the water heater is hanging, and the water heater condensate line is now hard-piped straight down and into the line so that the condensate runs outside without a trap or vent. The Sanicondens Best Flat is capable of serving multiple mechanical systems up to a combined total of 500,000 Btu per hour. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References.